EVS SOLDER RECOVERY

STANDARD STAND ALONE FILTER (SAF ) 8/10-250

Recommended Filter Replacement is as follows:-

    Normal Working
1-2 Wave Single Shift
No Clean/Low Solids Fluxes
High Rosin Fluxes,
Lead Free Solders
or
Multi Shift Working
New Pre Filter
8/10-250-PRE
  Replace every 10 Cycles Replace every 5 Cycles
COMBI Filter
8/10-250-Combi
Cleaned Weekly Replace at Week 10 / 12
or on inspection
Replace at Week 6 / 8
or on inspection
Hepa/Carbon Filter
8/10-250-HC
Cleaned Weekly Replace between 9-12 Months or on inspection Replace between 8-10 Months or on inspection

IMPORTANT NOTICE

PLEASE REPLACE THE FILTERS WITHIN THESE SCHEDULES AS INCORRECTLY MAINTAINED FILTERS WILL BLOCK THE AIR FLOW TO THE FAN. USING NON STANDARD FILTERS CAN CAUSE AIR FLOW PROBLEMS AND INVALIDATE THE WARRANTY.

 These figures are advisory and will vary with adherence to cleaning and service schedules and on fluxes and processes in use at each location. No Clean Fluxes and Low Solids may extend the schedule above.

Weekly Maintenance Schedule

 EACH WEEK please VACUUM each filter in the filter stack. This will greatly enhance the effectiveness and longevity of the filters and pay dividends in the long run.

ALL FILTERS MUST BE FITTED IN ACCORDANCE WITH DIRECTION ARROWS.

PLEASE REPLACE IN CORRECT ORDER

WARNING : When the filter is removed from the machine please remember to wear gloves and mask. Then it should be SEALED in a plastic bag and disposed of safely. Thank you.

Fuse Replacement

The Stand Alone Filter has its own 2 amp fuse for electrical protection. This is housed in a small push out fuse holder located just above the on off switch.

Configuration of Filters – Standard SAF

This unit has three Air inlets, one for the main body of the machine which connects from the top extraction to the inlet below the handle; the other two are blanked for potential use with high solids fluxes.

The filters used in the standalone filtration unit are as follows:

a) Hepa/Carbon Filter
Part No 8/10-250-HC
250x250x116mm
Impregnated deep bed split into 9 equal cells.
Specially constructed moulded polypropylene with bonded material membrane. Weight approx 5.0Kg - 12.0lbs
b) Combination Filter
Part No 8/10-250-Combi

250 x 250 x 105mm
Specially constructed HIGH FLOW COMBINATION PANEL FILTER with electrostatic properties.
Enhanced solids capture capacity and longer life.
c) New Pre Filter
No: 8/10-250-HS-PRE


New HS Pre Filter to prolong life of the Combination Filter

NEW CONFIGURATION – COMBINATION FILTER 8/10-250-COMBI FILTER CONFIGURATION

 

CLEANING/CHANGING THE FILTERS

 

web: www.solderrecovery.com